Passive self-regulation for underfloor heating Although underfloor heating systems are used in association with temperatures controls with different degrees of sophistication, the underfloor heating system provides its own passive self regulation. Floor temperatures are slightly higher then those of the room air. A rise in air temperature due to solar gain or increased occupancy means that […]

Underfloor Heating, Chippenham, Wiltshire

55 sqm concrete floor underfloor heating for Chippenham.  Four underfloor heating zones.  As below; – Family room – 110 m – one room thermostat – Study – 50 m – one room thermostat – Utility – 50 m – one room thermostat – Hall/WC – 90 m – one room thermostat Below is the underfloor […]

Underfloor Heating, Barnsley, Yorkshire

75 sqm underfloor heating system with six programmable digital room thermostats. Our local underfloor heating installer for the north of england will install the underfloor heating system. GF is 40 sqm screeded floor with 65 mm screed and 75 mm HD insulation.  The system will use a two port manifold.  One loop is for the […]

Underfloor Heating Mixing Valve Set Up

The thermostatic blending valve of our underfloor heating systems has a number of preset temperature settings. These range between 35°C and 60°C, as shown below: Min 35°C 1 40°C 2 44°C 3 48°C 4 50°C 5 54°C 6 58°C Max 60°C Initial settings of the thermostatic blending valve (after the heat up/screed drying period) should […]

Danfoss Wiring Centre FH-WC Technical Information

The FH-WC offers an eight zone wiring centre for underfloor heating systems that use hard-wired thermostats. With each of its eight outputs, the device can connect thermal actuators to the thermostats located in each room the underfloor heating is installed in. As the FH-WC is designed for use with water-based underfloor heating systems, it works […]

Underfloor Heating Fault Finding

FAULT FINDING SHEET In the event that your underfloor heating (UFH) system is not working correctly, here are some points to check to help find the cause of the problem: Check that the air is completely out from the system. Do not fill from the boiler; fill the UFH system as described in the instructions. […]

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
Shopping cart close