75 sqm underfloor heating system with six programmable digital room thermostats.
Our local underfloor heating installer for the north of england will install the underfloor heating system.
GF is 40 sqm screeded floor with 65 mm screed and 75 mm HD insulation. The system will use a two port manifold. One loop is for the Lounge – 110 m and the other loop is for the Kitchen – 90 m.
See project information below;
Pipe spacing approximate c/c 200 mm – c/c 250 mm. Max loop length 110 m. Try to use all the pipework supplied, but you will always have waste. Just make sure you have enough pipe to come back to the manifold, the pipe is marked every metre.
Loop lengths are only approximates! Read the instructions provided before installing the system.
Layout suggested is;
GF, MANIFOLD LOCATED AS DRAWING
Two room thermostats (2 core + earth). 2 Circuit Manifold.
LOOP LAYOUT (ONLY APPROXIMATE LOOP LENGTHS)
LOUNGE – 110 M – ONE ROOM THERMOSTAT
KITCHEN – 90 M – ONE ROOM THERMOSTAT
Pipe spacing approximate c/c 200 mm. Max loop length 110 m. Try to use all the pipework supplied, but you will always have waste. Just make sure you have enough pipe to come back to the manifold, the pipe is marked every metre.
Loop lengths are only approximates! Read the instructions provided before installing the system.
Layout suggested is;
FF, MANIFOLD LOCATED AS DRAWING
Four room thermostats (2 core + earth). 4 Circuit Manifold.
LOOP LAYOUT (ONLY APPROXIMATE LOOP LENGTHS)
LARGE BEDROOM 17 SQM – 110 M – ONE ROOM THERMOSTAT
MEDIUM BEDROOM 10 SQM – 90 M – ONE ROOM THERMOSTAT
SMALL BEDROOM – 60 M – ONE ROOM THERMOSTAT
LANDING/BATHROOM – 40 M – ONE ROOM THERMOSTAT